Configuring a Honeywell Xenon Scanner to be GS1 compliant

If the following data is encoded in a 128 symbol

{Start C}{Function 1} ]1710091510123456789012{Function 1}2002

where the first Function 1 after the Start C symbol indicates it’s a GS1 bar code and the second Function 1 is a delimeter after a variable length field. When a scanner reads this symbol it should output:

]C11710091510123456789012<GS>2002

Note the output starts with a [C1 indicating a Code 128 GS1 symbol and the second Function 1 code gets translated to an ASCII Group Separator character <GS>, or Hex 1D

The Xenon does not do this by default, but if you scan these two configuration labels, it will behave per the GS1 spec: